Products Description
Fiber Reinforced Self-Adhered Waterproofing Membrane
Name | Fiber Reinforced Self-Adhered Waterproofing Membrane |
Brand | HongGu |
Material | modified bitumen |
packaging | palletize |
Certification | CE, BBA, SGS, ISO, SIRIM, ASTM |
Advantage | High Elasticity and Flexibility,Excellent Waterproofing,Excellent Waterproofing,Excellent Waterproofing |
Application Methods | self-adhesive |
Leading time | Production within 7 days after receipt of deposit and confirmation of all details |
Business Type | Manufacture/Factory |
※ Product Description
The Fiber Reinforced Self-Adhered Waterproofing Membrane is an advanced, high-performance solution designed to offer superior waterproofing, durability, and strength. Reinforced with fibers, this membrane provides enhanced tear resistance and long-lasting protection against water infiltration in both horizontal and vertical applications. It’s perfect for use in commercial, industrial, and residential projects such as foundations, roofs, basements, and other critical waterproofing areas.
This membrane combines the strength of fiber reinforcement with the convenience of self-adhesion, simplifying installation while maintaining maximum effectiveness.
※ The name of SBS Torch Applied Modified Bituminous Waterproofing Membrane
Fiber Reinforced Self-Adhered Waterproofing Membrane | Fiber-Reinforced Peel and Stick Waterproofing Membrane |
Мембрана гидроизоляционная самоклеющаяся с армированием | Fiber-Reinforced Waterproofing Sheet |
Membrane d'étanchéité auto-adhésive renforcée par des fibres | Membrane imperméable autoadhésive renforcée en fibre |
Faserverstärkte Selbstklebende Abdichtungsbahn | Faserverstärkte Selbstklebende Abdichtungsmembran |
Membrana Impermeabilizante Autoadhesiva Reforzada con Fibra | Membrana Impermeabilizante Autoadhesiva con Refuerzo de Fibra |
Membrana Impermeabilizzante Autoadesiva Rinforzata con Fibra | 繊維強化自己粘着防水膜 |
自己粘着防水シート繊維強化型 | 섬유 강화 자착 방수막 |
※ Executive Standard
GB/T35467-2017
※ Application
Thickness | Width | Length |
1.2MM | 1M | 20M |
1.5MM | 1M | 20M |
2.0MM | 1M | 15M |
3MM | 1M | 10M |
4MM | 1M | 7.5/10M |
5MM | 1M | 7.5/10M |
※ Material Features
Fiber Reinforcement:
Strength and Durability: Reinforced with high-strength fibers, the membrane offers exceptional tear resistance, ensuring it can withstand mechanical stress and punctures.
Stability: The added fiber layer improves dimensional stability, preventing deformation and shrinkage, especially in fluctuating temperatures.
Self-Adhering Backing:
Easy Installation: The membrane features a strong self-adhesive layer, eliminating the need for hot asphalt or mechanical fastening systems. This reduces labor costs and application time.
No Need for Heat Welding: The self-adhesive property ensures a strong bond without requiring heat welding, making it safer and more efficient to apply.
Superior Waterproofing:
Seamless Barrier: Once installed, it forms a continuous, seamless waterproof barrier, preventing water infiltration and protecting the structure from moisture damage.
Excellent Bonding: The adhesive provides strong bonding with various substrates, including concrete, wood, and metal, ensuring a reliable seal.
Temperature and UV Resistance:
Extreme Temperature Tolerance: Designed to resist extreme heat and cold, the membrane remains flexible in freezing temperatures and resists softening in high heat, making it suitable for a wide range of climates.
UV Protection: Built-in UV resistance protects the membrane from degradation due to prolonged sun exposure, extending its lifespan.
Versatile Applications:
Suitable for both below-grade and above-grade applications, the membrane can be used on foundations, roofs, basements, tunnels, terraces, and more.
Compatibility with Various Substrates: Compatible with concrete, masonry, metal, wood, and insulation boards, making it an adaptable waterproofing solution.
※ Application
Foundations: Provides reliable waterproofing for foundations, protecting them from groundwater and moisture-related issues.
Roofs: Ideal for both flat and sloped roofs, offering superior protection from rain, snow, and wind-driven water.
Basements: Ensures that below-grade structures remain dry, even in areas with high groundwater levels.
Balconies and Terraces: Protects against water penetration in areas exposed to rain and weather elements.
Bathrooms and Wet Areas: Effective waterproofing for wet areas beneath tiles in bathrooms, kitchens, and laundry rooms.
Bridges and Tunnels: Used in civil engineering projects to protect infrastructure from water damage.
※ Construction Methods
self-adhesive
Technical Specifications:
Material Composition: Fiber-reinforced bituminous or synthetic rubber layer, integrated with a high-performance self-adhesive.
Thickness: 1.5mm to 3.0mm, customizable based on project requirements.
Tensile Strength: High tensile strength due to the fiber reinforcement, offering superior tear resistance.
Temperature Resistance: Capable of withstanding temperatures from -25°C to 120°C (-13°F to 248°F).
Waterproofing Capabilities: Fully waterproof, with a hydrostatic pressure resistance that ensures protection against water intrusion even under high pressure.
UV Resistance: Integrated UV protection ensures prolonged durability in exposed areas.
Installation Guidelines:
Surface Preparation:
The surface must be clean, dry, and free from dust, oil, and debris. Uneven or rough surfaces should be smoothed out, and cracks or voids should be repaired before installation.
Apply a primer if required, especially for porous substrates like concrete or masonry.
Application Process:
Measure and cut the membrane to the required length.
Remove the release liner from the adhesive side and position the membrane on the prepared surface.
Press down firmly, ensuring full contact with the substrate. Use a roller to remove any air pockets or wrinkles, ensuring a tight bond.
Overlap adjacent sheets by at least 50-75mm (2-3 inches) to create a watertight seal.
Seams and Joints:
Ensure proper overlap of seams for complete waterproofing. Consider using a double layer of membrane at critical points like corners and edges.
For areas that require additional reinforcement, apply a sealing tape or use a secondary layer of membrane.
Curing Time:
Since this is a self-adhered membrane, there is no curing time required. Once applied, it immediately provides waterproofing protection.
Maintenance:
Regular inspections should be conducted to identify any areas of wear, damage, or possible leaks.
If damage is detected, repairs can be made easily by applying new membrane layers over the affected area.
Safety and Handling:
Always wear protective gloves and eyewear when handling the membrane, particularly during cutting and installation.
Store the membrane rolls in a cool, dry place, away from direct sunlight and sources of heat.
Ensure proper ventilation in enclosed spaces to avoid fume buildup.
Environmental Considerations:
The membrane is environmentally friendly, containing no harmful chemicals or heavy metals.
It can be recycled or safely disposed of at the end of its lifespan, aligning with sustainable building practices.
Why Choose Our Fiber Reinforced Self-Adhered Waterproofing Membrane?
Enhanced Durability: The combination of fiber reinforcement and self-adhesive properties results in a membrane that stands up to mechanical stress, temperature fluctuations, and environmental challenges.
Simplified Installation: The self-adhering design saves time and labor, making it easier to apply than traditional waterproofing systems.
Wide Range of Applications: Suitable for numerous construction projects, this membrane provides reliable, long-term waterproofing protection for both residential and commercial structures.
※ Storage and Transport
1. Products of different types or specifications shall not be mixed in stock.
2. SBS elastomeric bitumen membrane should be kept dry and ventilated, without exposure to the sun or rain.
3. The temperature of the storage shall not be higher than 45 ℃. Stockpile the membranes flatwise, whose stockpile height shall not exceed five layers.
4. Prevent tilt or side pressure during transportation. Felt covering is required if necessary.
5. Time of storage shall at least be one year from the date of manufacture, under normal storage conditions for the product.